SEPAMAT F20 System Separator
overview:
in stock
-1plus 19% VAT plus Shippment
incl. VAT. plus Shippment
Sepamat
General information on system separation A backflow preventer separates the drinking-water system from the consumer system and protects drinking water from contamination by the backflow of substances from the consumer system. A backflow preventer is installed between the municipal drinking-water system and one or more consumers. These must be separated in accordance with Category 5 of the current drinking water regulations contained in DIN EN 1717.
Areas of applications of backflow preventers
- Medical sector (dental treatment centres...)
- Agriculture (livestock watering)
- Abbatoirs
- Car-wash facilities
- Irrigation systems
- Laundries
- Crematoriums
- Laboratories
- Utility water systems
The DVGW-certified, fully automated and pre-connected backflow prevention station must ensure that drinking water and Category 5 fluids are separated in accordance with DIN EN 1717. The integrated pump delivers water to consumers as required from a separation feed tank. The water level in the separation feed tank is regulated by a float valve. The drinking-water network and an emergency overflow are connected to the separation tank.
You can find more information at www.intewa.com
description | unit | value |
---|---|---|
Height | cm | 59,5 |
Breite | cm | 26,5 |
Länge | cm | 55 |
Gross weight | Kg | 26,1 |
Emergency overflow connection | DN | 50,0000 |
Power consumption | kW | 800 |
Max. flow rate | l/min | 90 |
Voltage | VAC / Hz | 230 / 50 |
Pump switch-on pressure | bar | 1,0 - 3.0 |
Sound pressure | dBA | 60 |
Protection class | IP | 44 |
Standby power | W | 16,0000 |
Mains water connection | " IG | 3/4 |
Permissible drinking water pressure | bar | 2,5 - 6 |
Operating pressure range | bar | 0 - 5,5 |
description | unit | value |
---|---|---|
Dimension cardboard (length x width x height) | mm | 645 x 615 |
Weight EU pallet max. loaded (truck)EU pallet max. loading | Stk | 9 |
Volume cardboard | m³ | 0,117 |
incl. VAT plus shippment
- for RAINMASTER F 20/40 and SEPAMAT F 20/40
- from version 2.3
incl. VAT plus shippment
- for RAINAMSTER F20 and SEPAMAT F20 pump
- 12,5 µF
incl. VAT plus shippment
- for RAINMASTER F 20/40, SC 20/40 and SEPAMAT F 20/40
- incl. infeed tube
- RMF 20/40 from version 2.0
- RMF SC 20/40 from version 1.0
incl. VAT plus shippment
incl. VAT plus shippment
- for RAINMASTER F 20/40, SC 20/40 and SEPAMAT F 20/40
- Cap and container securing
- Installation wrench
- Flat seal
incl. VAT plus shippment